Qualube Hydraulic HM46
is recommended for your SUMITOMO (CYCLO DRIVE)
Recommendations for your SUMITOMO (CYCLO DRIVE)
All our lubricants are designed to meet all the required standards and requirements of the Original Equipment Manufacturers, as well as ensuring the latest ACEA and API quality recommendations. If you need any help choosing or locating the right oil for your engine or equipment please contact us and we will be happy to help.
Operating elements & bearings (-10°C ... 5°C)
Recommendation
Product 1
Qualube Hydraulic HM46
Product 2
Qualube Hydraulic HM68
Product 3
Qualube Hydrapower HV46
Capacity
0.7 - 70.0 (ltr)
Notes
- a. Depending on the size and mounting position (horizontal or vertical) forced lubrication systems may be used. Grease lubrication is used on some smaller units as follows: ambient minus 10°C to 50°C; maintenance free units are filled with Shell Alvania RA at factory; other units Shell Alvania 2 or Cosmo Dynamax 2 recommended
- b. Viscosity specification: minimum at operating oil temperature 15 cSt.; maximum at start up, oil bath lubrication 4300 cSt., forced oil circulation 2200 cSt. (for pump start). High viscosity index oils are recommended
Operating elements & bearings (0°C ... 35°C)
Recommendation
Product 1
Qualube Hydraulic HM100
Product 2
Qualube MEP 100
Product 3
Qualube MEP 150
Capacity
0.7 - 70.0 (ltr)
Notes
- a. Depending on the size and mounting position (horizontal or vertical) forced lubrication systems may be used. Grease lubrication is used on some smaller units as follows: ambient minus 10°C to 50°C; maintenance free units are filled with Shell Alvania RA at factory; other units Shell Alvania 2 or Cosmo Dynamax 2 recommended
- b. Viscosity specification: minimum at operating oil temperature 15 cSt.; maximum at start up, oil bath lubrication 4300 cSt., forced oil circulation 2200 cSt. (for pump start). High viscosity index oils are recommended
Operating elements & bearings (30°C ... 50°C)
Capacity
0.7 - 70.0 (ltr)
Notes
- a. Depending on the size and mounting position (horizontal or vertical) forced lubrication systems may be used. Grease lubrication is used on some smaller units as follows: ambient minus 10°C to 50°C; maintenance free units are filled with Shell Alvania RA at factory; other units Shell Alvania 2 or Cosmo Dynamax 2 recommended
- b. Viscosity specification: minimum at operating oil temperature 15 cSt.; maximum at start up, oil bath lubrication 4300 cSt., forced oil circulation 2200 cSt. (for pump start). High viscosity index oils are recommended
Oil Change Intervals
Operating elements & bearings (-10°C ... 5°C)
Hours Max | 25000 |
Operating elements & bearings (0°C ... 35°C)
Hours Max | 2500 |
Operating elements & bearings (30°C ... 50°C)