Close Print
Application
Recommendation
Capacity (ltr)
Operating elements & bearings (-10°C ... 5°C)
Product 1
Qualube Hydraulic HM46 (a, b)
0.7 - 70.0
Product 2
Qualube Hydraulic HM68
Product 3
Qualube Hydrapower HV46
Operating elements & bearings (0°C ... 35°C)
Product 1
Qualube Hydraulic HM100 (a, b)
0.7 - 70.0
Product 2
Qualube MEP 100
Product 3
Qualube MEP 150
Operating elements & bearings (30°C ... 50°C)
Product 1
Qualube MEP 220 (a, b)
0.7 - 70.0
Product 2
Qualube MEP 320

Lubricant / Capacity Notes

a. Depending on the size and mounting position (horizontal or vertical) forced lubrication systems may be used. Grease lubrication is used on some smaller units as follows: ambient minus 10°C to 50°C; maintenance free units are filled with Shell Alvania RA at factory; other units Shell Alvania 2 or Cosmo Dynamax 2 recommended
b. Viscosity specification: minimum at operating oil temperature 15 cSt.; maximum at start up, oil bath lubrication 4300 cSt., forced oil circulation 2200 cSt. (for pump start). High viscosity index oils are recommended

General Notes

There are no notes to display for this model

Oil Change Intervals

Operating elements & bearings (-10°C ... 5°C)
Hours Max 25000
Operating elements & bearings (0°C ... 35°C)
Hours Max 2500
Operating elements & bearings (30°C ... 50°C)
Hours Max 2500