Application |
Recommendation |
Capacity (ltr) |
|
---|---|---|---|
Engine (DT) (Cat C9 ACERT 196kW)
|
Product 1
|
Qualube Extremol 15W40 (a, b) |
32.0
|
Product 2 |
Qualube Extremol 10W40 | ||
Product 3 |
Qualube Supremol 10W40 | ||
Transmission
|
From Hydraulics |
|
|
Final Drive (Each)
|
Qualube Hi-Q-4 50 (c, d, e) |
28.5
|
|
Coolant
|
Qualube Qualguard ORATEC Coolant (f) |
44.0
|
|
Hydraulics
|
Product 1
|
Qualube Eurofleet 10 (g, h, i, j, k) |
189
|
Product 2 |
Qualube Hi-Q-4 10 | ||
General grease points
|
Qualube Lithium Complex Moly EP2M (l) |
|
|
Equalizer Bar End, Pin Joint
|
Product 1
|
Qualube Syntogear SA 75W-140 (m, n) |
|
Product 2 |
Qualube HD EP 85W140 | ||
Product 3 |
Qualube LSHDEP 85W140 | ||
Pivot Shaft Bearings (Each)
|
Qualube Hi-Q-4 50 (o, p, q, r) |
3.0
|
|
Track Roller Frame Recoil Spring
|
Qualube Hi-Q-4 50 (s, t, u, v) |
|
|
Track Rollers & Idlers
|
Product 1
|
Qualube Extremol 15W40 (w) |
|
Product 2 |
Qualube Extremol 10W40 | ||
Product 3 |
Qualube Supremol 10W40 |
a. | -10°C to 50°C |
b. | Alternative recommendations, -18°C to 40°C: Qualube Extremol FS 10W30 / Qualube Supremol 5W30 |
c. | -15°C to 50°C |
d. | Alternative recommendations, -30°C to 25°C: Qualube Hi-Q-4 30 |
e. | Alternative recommendations, -25°C to 25°C: Qualube Hi-Q-4 30 |
f. | Mix ratio, 50% >-37°C |
g. | -20°C to 40°C |
h. | Alternative recommendations, -20°C to 40°C: Qualube Hi-Q-4 10; Qualube Extremol FS 10W30 / Qualube Supremol 5W30 |
i. | Alternative recommendations, -15°C to 50°C: Qualube Hi-Q-4 30 |
j. | Alternative recommendations, -5°C to 45°C: Contact with our Technical Team |
k. | Alternative recommendations, 0°C to 50°C: Qualube Endurol 15W40 |
l. | Alternative recommendations: Contact with our Technical Team |
m. | -10°C to 50°C |
n. | Alternative recommendations, -20°C to 40°C: Qualube HD EP 80W90 / Qualube Syntogear TDL 80W90 / Qualube LS HD EP 80W90 |
o. | 0°C to 50°C |
p. | Alternative recommendations, -25°C to 25°C: Qualube Hi-Q-4 30 |
q. | Alternative recommendations, -20°C to 25°C: Qualube Hi-Q-4 30 |
r. | Alternative recommendations, -10°C to 40°C: Contact with our Technical Team |
s. | 0°C to 50°C |
t. | Alternative recommendations, -25°C to 25°C: Qualube Hi-Q-4 30 |
u. | Alternative recommendations, -20°C to 25°C: Qualube Hi-Q-4 30 |
v. | Alternative recommendations, -10°C to 40°C: Contact with our Technical Team |
w. | -10°C to 50°C |
There are no notes to display for this model
Months Max | 3 |
Hours Max | 500 |
Months Max | 12 |
Hours Max | 2000 |
Months Max | 12 |
Hours Max | 2000 |
Months Max | 18 |
Hours Max | 3000 |
Copyright © OATS Ltd. 2024