Close Print
Application
Recommendation
Capacity (ltr)
Engine (D) (Komatsu SAA4D107E-2, 4.5L, 110kW, EGR, DOC)
Product 1
Qualube Extremol FS 10W30 (a, b, c, d)
18.0
Product 2
Qualube Supremol 5W30
Transmission
From Hydraulics
Coolant (Engine)
Qualube Qualguard ORATEC Coolant (e)
23.0
Coolant (Hybrid device)
Qualube Qualguard ORATEC Coolant (f)
6.0
Hydraulics
Contact with our Technical Team
132
Hydraulics (Breaker 100%/50%)
Contact with our Technical Team
132
Grease
Qualube Lithium Complex 2 (g)
Damper Case
Qualube Hi-Q-4 30 (h, i)
Final Drive Case (each)
Qualube Hi-Q-4 30 (j, k)
5.0
Generator Motor Case
Qualube Hi-Q-4 10 (l, m)
6.0
Swing Machinery Case
Qualube Hi-Q-4 30 (n, o)
6.5
Swing Machinery Case (Electric)
Qualube Hi-Q-4 10 (p, q)
1.6

Lubricant / Capacity Notes

a. -20°C to 40°C
b. Alternative recommendations, -25°C to 40°C: Contact with our Technical Team
c. Alternative recommendations, -25°C to 35°C: Contact with our Technical Team
d. Alternative recommendations, -15°C to 40°C: Qualube Extremol 15W40 / Qualube Extremol 10W40 / Qualube Supremol 10W40
e. Mix ratio, 30% >-30°C
f. Mix ratio, 30% >-30°C
g. Alternative recommendations: Qualube Lithium EP 2 / Qualube Lithium Complex 2
h. -30°C to 50°C
i. Alternative recommendations, -30°C to 50°C: Contact with our Technical Team
j. -30°C to 50°C
k. Alternative recommendations, -30°C to 50°C: Contact with our Technical Team
l. -30°C to 40°C
m. Alternative recommendations, -30°C to 40°C: Contact with our Technical Team
n. -30°C to 50°C
o. Alternative recommendations, -30°C to 50°C: Contact with our Technical Team
p. -30°C to 40°C
q. Alternative recommendations, -30°C to 40°C: Contact with our Technical Team

General Notes

There are no notes to display for this model

Oil Change Intervals

Engine (D) (Komatsu SAA4D107E-2, 4.5L, 110kW, EGR, DOC)
Hours Max 500
Coolant (Engine)
Months Max 24
Hours Max 4000
Coolant (Hybrid device)
Months Max 24
Hours Max 4000
Hydraulics
Hours Max 5000
Hydraulics (Breaker 100%/50%)
Hours Min 1000
Hours Max 1500
Damper Case
Hours Max 1000
Final Drive Case (each)
Hours Max 2000
Generator Motor Case
Hours Max 1000
Swing Machinery Case
Hours Max 1000
Swing Machinery Case (Electric)
Hours Max 1000