Close Print
Application
Recommendation
Capacity (ltr)
Hydraulics
Product 1
Qualube Hydraulic HM46 (a, b, c, d, e, f, g, h)
Product 2
Qualube Hydrapower HV46

Lubricant / Capacity Notes

a. Viscosity limits: Recommended operating viscosity, 30 to 50 cSt. Max. at cold start, 1000 cSt. Minimum for continuous operation, 18 cSt. Minimum in emergency, 10 cSt. Fluid temperature range, -30°C to 80°C
b. Consult manufacturer if HFB, HFC, HFD or biodegradable fluids are to be used
c. 38°C to 50°C
d. Alternative recommendations, 23°C to 33°C: Qualube Hydraulic HM22 / Qualube Hydrapower HV22
e. Alternative recommendations, 32°C to 42°C: Qualube Hydraulic HM32 / Qualube Hydrapower HV32
f. Alternative recommendations, 46°C to 58°C: Qualube Hydraulic HM68 / Qualube Hydrapower HV68
g. Alternative recommendations, 55°C to 68°C: Qualube Hydraulic HM100 / Qualube Hydrapower HV100
h. Alternative recommendations, 63°C to 75°C: Qualube Hydraulic HM150 / Qualube Hydrapower HV150

General Notes

There are no notes to display for this model

Oil Change Intervals

There is no Oil Change Interval data to display for this model