Application |
Recommendation |
Capacity (ltr) |
|
---|---|---|---|
Hydraulic System
|
Product 1
|
Qualube Hydraulic HM100 (a, b, c, d, e, f, g, h, i, j, k) |
|
Product 2 |
Qualube Hydrapower HV100 |
a. | Use DIN HLP for piston pumps and all applications at operating pressures over 200 bar. Mobile plant applications may use heavy duty SAE 10/20/30 engine oils of appropriate viscosity - refer to manufacturer's individual specification details |
b. | Viscosity grade selection criteria: recommended viscosity range at operating temperature 20 - 100 cSt.; maximum 800 cSt. (2000 cSt. for short period during start up); minimum permitted 12 cSt. Recommended operating temperature range 40° - 90°C |
c. | Recommended cleanliness standard; varies according to application. Generally for pumps and valves; NAS 1638 class 9/ISO 4406 18/15 above 160 bar, NAS 1638 class 10/ISO 4406 19/16 below 160 bar |
d. | Fire resistant fluids type HFA/HFB/HFC/HFD are acceptable. Manufacturer uses the CETOP coding system and should be consulted for information on speed/pressure de-rating and suitability of individual pumps/motors |
e. | 40°C to 80°C |
f. | Alternative recommendations, 10°C to 43°C: Qualube Hydraulic HM22 / Qualube Hydrapower HV22; Contact with our Technical Team |
g. | Alternative recommendations, 18°C to 52°C: Qualube Hydraulic HM32 / Qualube Hydrapower HV32; Contact with our Technical Team |
h. | Alternative recommendations, 25°C to 62°C: Qualube Hydraulic HM46 / Qualube Hydrapower HV46; Contact with our Technical Team |
i. | Alternative recommendations, 33°C to 70°C: Qualube Hydraulic HM68 / Qualube Hydrapower HV68; Contact with our Technical Team |
j. | Alternative recommendations, 40°C to 80°C: Contact with our Technical Team |
k. | Alternative recommendations, 47°C to 90°C: Qualube Hydraulic HM150 / Qualube Hydrapower HV150 |
There are no notes to display for this model
Hours Min | 2000 |
Hours Max | 4000 |
Copyright © OATS Ltd. 2024